Hacker News new | past | comments | ask | show | jobs | submit
> The reason is that if you add up the average time it takes to get the go-ahead through my monitor’s hub, which is around 7.6 µs, to the average time it takes to send 4 KB, around 8.2 µs, you can find what the maximum speed is.

This part is saying the NIC with this monitor can transfer 4 KB to the host through the USB hub every 15.8 us. You can do the math and it's about 2gbps.

Remove the hub, and reduce the delay solves the problem.

Increase the burst size would work: 8 KB per 24.0 us would be sufficient for 2.5 gbps.

Increase the burst size and the transfer rate as done with the 5 gbps adapter, and that should work out, although that one is probably going to be insufficient for full rate 5 gbps as well.

Yes, that is correct. I had misunderstood which connection cibyr was referring to, see sibling post.